Skip to content

About

Reproducibility release for 49Ti nuclear-spin qudit addressability and control on MgO/Ag(100), with frozen data, analysis scripts, and hardware benchmarks.

Topics

Resources

Stars

0 stars

Watchers

0 watching

Forks

Repository files navigation

surface-ti49-qudit-addressability

Reproducibility material for “Quadrupole-limited control windows for an atomically addressable 49Ti nuclear-spin qudit.”

Version 2.0.0 extends the original release with the experimentally accessible low-field robustness calculation, dense dual-manifold control thresholds, the field-quadrupole design map, and a one-at-a-time sensitivity decomposition.

Main scientific outputs in v2.0.0

  • closed-form rigid-comb addressability, including the explicit absolute-frequency/order-reversal derivation;
  • general maximum-field rule for a hyperfine-coupled quadrupolar nucleus;
  • validated 16-level sensitivity scan around the low-field maximum;
  • minimax field B = 1.0292 T, with worst sampled separation 1.187772 MHz;
  • contiguous >= 1 MHz low-field interval 0.992-1.069 T;
  • static dual-manifold 99% first-crossing rates of 4.815 kHz at 1.35 T and 21.9289 kHz at 1.0292 T;
  • one-at-a-time sensitivity showing dominant leverage from kappa and A_perp/A_z;
  • field-quadrupole design map and hard ceiling Delta_max = |kappa|/28 for 49Ti.

The control propagation conditions on a static electron manifold. The manuscript explicitly treats electron switching as a separate experimental requirement and does not interpret the static result as a complete driven-dissipative gate prediction for the present STM junction.

Layout

  • scripts/ - calculation scripts and the historical 16-level/control model required by the revised analysis.
  • data/v2/lowfield/ - validation and low-field field-scan outputs.
  • data/v2/control/ - dense control sweeps and publication-facing threshold summary.
  • data/v2/sensitivity/ - one-at-a-time sensitivity tables.
  • data/v2/design/ - compact field-quadrupole design outputs.
  • figures/v2/ - final publication figures.
  • manuscript/ - revised manuscript and Supplementary Information source/PDF.

Environment

The v2 extension requires Python 3 with NumPy, SciPy, pandas and Matplotlib. The original repository environment remains suitable for the manuscript-level scripts.

Reproduction sequence

From the repository root:

python scripts/qst_lowfield_full16_scan.py --out data/v2/lowfield_recomputed
python scripts/qst_oat_sensitivity.py
python scripts/qst_B_kappa_design_map.py --out data/v2/design_recomputed

The time-dependent fourteen-tone propagation is substantially more expensive. The exact dense outputs used in the manuscript are supplied in data/v2/control/, and the corresponding source scripts are retained in scripts/.

Versioning and Zenodo

The existing Zenodo concept DOI is 10.5281/zenodo.21969249. After updating the GitHub repository, create a GitHub release tagged v2.0.0 so Zenodo archives the revised release and mints a new version-specific DOI. Insert that version DOI into the final publication proof.

Citation

Please cite the version-specific Zenodo release together with the accompanying manuscript.

License

Code: MIT. Derived data and original figures: CC BY 4.0 unless a third-party source is explicitly identified.

About

Reproducibility release for 49Ti nuclear-spin qudit addressability and control on MgO/Ag(100), with frozen data, analysis scripts, and hardware benchmarks.

Topics

Resources

Stars

0 stars

Watchers

0 watching

Forks

Releases

Packages

Contributors

Languages