Repository navigation
Add Corning 3337 24-well plate labware - #61
Draft
kingbedjed wants to merge 2 commits into
Draft
kingbedjed wants to merge 2 commits into
kingbedjed wants to merge 2 commits into
Conversation
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This was referenced Nov 13, 2026
This branch has not been deployed
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
The request
Slack user
U0APRMP9RH8in#labware-requests, 2026-11-13 (permalink):Closes #60
Decisions needed
Corning_costar_24_well_plate.json(3524) andCorning_3527_24_well_plate.jsonare already in the registry with the same footprint, pitch and A1 offsets. This pull request adds 3337 as its own entry so it can be found by its catalogue number, as 3527 was added beside 3524 (and as Add Corning 3336 12-well plate labware #59 does for the 12-well CellBIND 3336). The alternative is to close this and point the requester at 3524.working_volume_min/working_volume_max. The Product Description gives one "working volume per well", 2 mL, which the existing 3524 entry quotes. Say if the 2 mL should be used instead.What is included
Corning_3337_24_well_plate.jsonPlus one row in
tests/test_labware.py.Figures
Corning's catalogue photo for 3337, from the product page:
Sources used
www.corning.comreturns 403 to plain curl. The drawing and the photo needed the full browser header set.Judgement calls
diameteris the well bottom (15.62 mm, Product Description and family sheet) anddiameter_topthe opening (16.26 mm, printed at the rim on the drawing). The existing 3524 and 3527 entries predate this convention and have the opening indiameter. This pull request leaves them as they are.floor_height3.81 mm is derived, as 2.54 + 1.27. Corning's vertical numbers do not close: depth + bottom thickness + bottom elevation = 21.21 mm against the printed 20.27 mm plate height. That is the same 0.94 mm gap as on the 6- and 12-well sheets. Each value is recorded as printed.skirt_height13.74 mm is from the family sheet. The drawing's side view draws the step lower (about 11.1 mm), but that view's vertical scale does not close against its own printed 22.63 mm, so nothing was scaled off it.upper_outlineis scaled off DWG01261 Rev B, assumed to scale. The top view draws the plate body inside the skirt, inset 1.89 mm (left) and 1.84 mm (top, right, bottom). The side view gives 1.78 / 1.70 mm at the two ends. The two corners at the column-6 end are rounded with r ≈ 12.0 mm, and the A1-end corners are square to within the drawn line. Calibration came from the printed 127.76 × 85.47 mm footprint (17.971 / 17.983 px/mm on a 600 dpi render), checked against the printed A1–D1 distance of 57.91 mm (0.45 % apart) and the 19.304 mm pitch (0.3 %). The uncertainty is about ±0.5 mm on the radius and ±0.15 mm on the insets.Testing
pytest -q: 192 passed.ruff check,ruff format --check,ty checkat CI's pins via pixi): all passed.The warning is expected: the drawing prints the off-centre grid (see Judgement calls).
🤖 Generated with Claude Code
Opened by the
add-labwareskill of ramona-claude 0.24.2 (ramona-llm ee2d4a6+dirty, prompt bc769991).