Repository navigation
Add Thermo Nunc OmniTray 264728 1-well plate labware - #57
Draft
kingbedjed wants to merge 2 commits into
Draft
kingbedjed wants to merge 2 commits into
kingbedjed wants to merge 2 commits into
Conversation
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
This branch has not been deployed
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
The request
Slack
#labware-requests(C0BT14F1GTF), userU0APRMP9RH8, 2026-11-13:https://ramonaoptics.slack.com/archives/C0BT14F1GTF/p1794599851078359?thread_ts=1794599851.078359&cid=C0BT14F1GTF
Closes #56
Decisions needed
Thermo_nunc_165218_1_well_plate.json(the Nunclon Delta treated OmniTray), so its geometry is identical. Onlyname,part_number,web_reference,last_updated,surface_treatments(untreated) and the opening ofnotesdiffer. The alternative is to close this and point the requester at 165218. I went with per-catalog-number entries so the plate can be found by the number on the box.What is included
Thermo_nunc_264728_1_well_plate.jsonFigures
Sources used
drawing_reference. One dimension block covers 165218, 242811, 264728 (clear, 10/90) and 465219. It is stamped NOT TO SCALE, so nothing was scaled off it.web_reference: untreated, sterile, lid, "Microplate dimension with 2 notched corners", 35 mL working and 90 mL capacity. These agree with the PSS.Judgement calls
These are all inherited unchanged from
Thermo_nunc_165218_1_well_plate.jsonand are documented in full innotes:width) by 72.9 mm (along the plate's width,height) is derived from the printed 84 cm² culture area as a uniform inset from the printed 123.7 × 81.3 mm body.diameterrepeats the shorter side, 72.9 mm.floor_height2.8 mm = tray height F − well depth G, both printed.skirt_thicknessandupper_outlineare derived from printed A/B and C/D.pitchis the plate width, because there is one well.bottom_thicknessandbottom_elevationare not recorded, because Thermo does not publish them.Testing
pytest -q: 192 passed. The new file has its own row intest_plate_definition_files_can_be_loaded.lint(CI's pixi command: ruff 0.15.22 check and format, ty 0.0.74): all checks passed.🤖 Generated with Claude Code
Opened by the
add-labwareskill of ramona-claude 0.24.2 (ramona-llm ee2d4a6+dirty, prompt bc769991).