Fan Control

Quiet rack servers, without cooking them.
Self-hosted fan control for Dell PowerEdge, Supermicro and HPE ProLiant, with a smart mode that learns your server, and the BMC as the safety net.

CI Release Image Python Dependencies License: MIT

Quick start · Hardware · How it works · Safety · Integrations · Changelog

The overview: three servers, each in its own fan mode

Why

Rack servers are made for datacenters, where nobody minds the noise. In a homelab the factory fan profile runs loud, and the usual fix, an ipmitool script in cron that pins the fans low, has a flaw: when the script dies, the fans stay low and nobody is watching the temperature.

Fan Control takes over the fans only while it is sure it should. It reads every sensor the BMC has, holds the temperature you choose with as little fan as possible, and hands the fans back to the BMC the moment anything is unknown: a missing reading, a sensor that disappears, a failed fan, a command the BMC ignores, a crash or a container stop. A watchdog restarts it if it stalls, and a small script on the host covers it being killed.

At a glance

A server's page: live readings and the last hour

The control panel: the fan curve, failsafe, minimum speed and quiet hours The server page on a phone

The Homarr widget
  • Four ways to drive the fans: automatic (the BMC), fixed, a curve you drag, or smart, which learns the speed each load needs on your server, sees heat coming before it arrives and rides out short bursts.
  • Protection first: a CPU failsafe, an exhaust air limit, every sensor's own BMC warning level, a minimum speed, a dry run to try things out. The BMC takes over whenever anything is wrong or unknown.
  • Every server in one place: scan your network for BMCs, let each say what it is, test it, add it. Monitoring-only servers (any Redfish or IPMI BMC) get the same history, alerts and metrics.
  • Quiet hours and schedules: cap the fans at night, or by day and hour, without giving up protection.
  • Alerts on Discord, ntfy, Gotify or any webhook: failsafe, failed fan, ignored commands, a hot room.
  • Prometheus metrics, a Grafana dashboard, alert rules, and Homarr widgets that share only what you choose.
  • Made to be left alone: plain Python with no dependencies, a non-root read-only container, read-only accounts, revocable sessions and tokens, backups, English and Portuguese, °C and °F.

Contents

Supported hardware · Quick start · Configuration · Fan control · Alerts · Integrations · Diagnostics · Accounts and security · Backup · Troubleshooting · Upgrading · Development · Contributing

Supported hardware

Type Servers Fan control Reads
Dell PowerEdge (iDRAC) iDRAC 6, 7, 8, and iDRAC 9 up to firmware 3.30.30.30 Yes IPMI
Supermicro X10, X11 and X12 boards Yes, experimental IPMI
HPE iLO 4, unlocked firmware ProLiant Gen8 / Gen9 with the community-patched iLO 4 2.77 Yes (caps over SSH), experimental Redfish
Redfish HPE iLO 4 (2.30+), iLO 5, iLO 6, Lenovo XCC, Dell iDRAC 9, most recent BMCs Monitoring only Redfish
Other IPMI Any BMC with IPMI over LAN Monitoring only IPMI
Demo Simulated readings Yes (simulated) —

Monitoring only means the vendor firmware offers no way to set fan speed. Those servers still get the overview card, history, alerts, reports, metrics and the widget, which is often enough to find what makes a server loud: on HPE, a third-party PCIe card or disk the iLO cannot read is the usual cause.

Dell iDRAC 9 from firmware 3.34.34.34, and iDRAC 10, no longer accept fan commands: add them as Redfish. Not sure what you have? Scan network and Detect on the Add server page ask the BMCs and pick the type for you. The scan only accepts private ranges, up to a /22, and only an admin can run it.

Quick start

1. Run the container

mkdir fan-control && cd fan-control
curl -O https://raw.githubusercontent.com/ST-DEVPT/rack-fan-control/main/docker-compose.yml
mkdir data && chown 1000:1000 data

Set WEB_PASSWORD (and TZ) in docker-compose.yml, then:

docker compose up -d

2. Open http://<docker-host>:8080, sign in, and choose Add server.

3. Find your servers: Scan network probes a private range (for example 192.168.1.0/24) for BMCs answering Redfish or IPMI and suggests the type of each; Use fills in the form. Or enter one address and press Detect, or pick the hardware yourself. Fill in the user and password and press Test connection: it reads the BMC once and shows the model, sensors and power draw before anything is saved.

Before adding a server, prepare its BMC:

  • Dell: enable IPMI over LAN (iDRAC Settings → Network → IPMI Settings); the user must be an Administrator.
  • Supermicro: IPMI over LAN is on by default; use an Administrator account.
  • HPE and other Redfish: any account that can read the system health. Redfish uses HTTPS (port 443).
  • HPE iLO 4 unlocked: SSH (port 22) and HTTPS must both be reachable, and the firmware must be the patched 2.77.

Images are built for linux/amd64 and linux/arm64. Use the major version tag, ghcr.io/st-devpt/rack-fan-control:2: it takes every fix and feature of 2.x and never a change that breaks your settings. :latest follows the main branch, :2.2 or :2.2.0 pin a release.

Configuration

Servers, fan settings and Discord are configured in the dashboard. The environment holds the rest:

Variable Default Description
WEB_PASSWORD empty Admin password. Empty disables sign-in; only do that on a trusted network
VIEW_PASSWORD empty Optional read-only account: sees everything, changes nothing
TZ UTC Time zone for quiet hours and the event log, e.g. Europe/Lisbon
CHECK_INTERVAL 15 Seconds between readings and fan commands. Minimum 5
DISCORD_WEBHOOK_URL empty Default Discord webhook. A webhook pasted in the dashboard takes precedence
METRICS_TOKEN empty A metrics token for /metrics (Authorization: Bearer <token>). Tokens can also be created on the Prometheus page
EMBED_TOKEN empty A widget token for /embed?token= and /api/widget. Tokens can also be created on the Homarr page
LOG_FORMAT text json prints one JSON object per log line (time, level, logger, server, message) for Loki, Graylog and the like
UPDATE_CHECK true Asks GitHub twice a day for the latest release, and shows it in the sidebar when it is newer. false turns it off
TRUST_PROXY off Set to true behind a reverse proxy, so sign-in limits and the event log use X-Forwarded-For
TRUSTED_PROXIES loopback and Docker networks Addresses or networks (comma separated) whose X-Forwarded-For is believed, e.g. 192.168.1.10 for a proxy on another machine
PORT 8080 HTTP port inside the container

Servers in the environment

Servers can also be declared in docker-compose.yml, for example to keep credentials in a .env file. They show up in the dashboard like the others, but can only be changed in the environment:

    environment:
      SERVER_1_NAME: Compute
      SERVER_1_DRIVER: dell              # dell, supermicro, ilo4-unlocked, redfish, ipmi or demo
      SERVER_1_HOST: 192.168.1.120       # "local" for IPMI from the server itself
      SERVER_1_USERNAME: root
      SERVER_1_PASSWORD: ${COMPUTE_BMC_PASSWORD}
      SERVER_2_NAME: DL360
      SERVER_2_DRIVER: redfish
      SERVER_2_HOST: 192.168.1.121
      SERVER_2_USERNAME: Administrator
      SERVER_2_PASSWORD: ${DL360_ILO_PASSWORD}
      SERVER_2_VERIFY_TLS: "false"       # BMCs ship self-signed certificates

The 1.x variables still work and keep their settings: IDRAC_HOST, IDRAC_USERNAME, IDRAC_PASSWORD, IDRAC_NAME for one server and IDRAC_1_HOST, ... for several.

What is stored in /data

File Contents
servers.json Servers added in the dashboard, with their BMC passwords (file mode 600, never sent to the browser)
settings.json, settings-<server>.json Mode, curve, targets, limits, quiet hours and the other fan settings
history-<server>.json Three hours of readings, seven days of 5-minute averages, and the events
alerts.json Alert settings, including the Discord webhook and the ntfy, Gotify and webhook addresses and tokens (file mode 600, never sent to the browser)
smart-<server>.json What smart mode learned: the fan speed each heat load needs
widget.json Which fields widgets may show
tokens.json Widget and metrics tokens, as SHA-256 hashes (file mode 600)
report-state.json Which Discord message the status card is edited into
known_hosts SSH host keys of unlocked iLO 4 servers, recorded on first connection
secret Key that signs sign-in sessions. Delete it to sign everyone out

Fan control

For servers whose type has fan control (Dell, Supermicro, unlocked iLO 4):

Mode What happens
Automatic The BMC runs its factory profile. Loudest, and the fallback for every problem
Fixed Every fan at one speed
Curve Speed follows the hottest CPU along points you drag. Start from a preset (quiet, balanced, cool, storage) or copy another server's curve
Smart Holds the CPU at a target you set with as little fan as it can, learning what each load needs, and keeps every other sensor clear of its limits

Smart mode

Smart mode watches the CPU against its target, the exhaust air against 8 °C below its limit, and every sensor with a BMC warning threshold against 8 °C below the point where the failsafe would trip. Inlet air is left out: no fan speed cools the room. It answers to whichever is worst, in four ways:

  • It learns your server. Whenever a load has been held steady at the target for a minute, it remembers the fan speed that did it, against the heat load: power draw over the room left between the inlet air and the target. When that load comes back, the fans go straight to what worked last time instead of waiting for the heat. A warm day or a new target needs no relearning, because the heat load already accounts for both. The server page draws what it has learned; Forget starts it afresh. It learns nothing during a dry run.
  • It looks ahead. Each temperature is judged where its trend over the last minute puts it 40 seconds later, so a CPU that is climbing gets air before it arrives.
  • It corrects itself. A proportional and integral trim on top fixes what the learned map gets wrong, and the map slowly takes the correction over.
  • It stays quiet. Fans rise at once, but fall only after lower demand has lasted the ramp-down delay, and then slowly, so a job that comes and goes every minute leaves them steady. Corrections under 2 % are ignored. At idle it rests on the minimum speed.

When something heads for its trip point, smart mode boosts the fans by 25 % at once, so the BMC rarely has to take over. During quiet hours the cap gives way gradually from 8 °C below a trip point: louder fans beat a failsafe.

Protection

The BMC takes over, whatever the mode, when:

  • the hottest CPU reaches the CPU failsafe;
  • the exhaust air reaches the exhaust air limit (on by default, empty turns it off);
  • any sensor comes within the margin (5 °C by default) of the warning threshold its BMC defines: PCIe cards, disks, DIMMs, the RAID controller, which a CPU-only curve would never see;
  • anything is unknown: there is no CPU reading (no other sensor ever stands in for the CPU), the BMC cannot be read (the fans are handed back as soon as it takes a command again), a temperature sensor that was there stops reporting or reports a fault, a fan fails, or the BMC ignored the last fan command;
  • the server is off, a fan command is refused, the control loop fails or stalls, the server is removed or the container stops.

Once a limit trips, the BMC keeps the fans for at least 5 minutes, and manual control resumes only when things are 3 °C below the limit, starting from 50 % and easing down; so the fans don't flap at the edge. Fans never run below the minimum speed (20 % by default, 10 % at the lowest: cards without a sensor, HBAs, NICs, NVMe drives and GPUs, are cooled by that airflow alone). Supermicro boards never go below 25 %, where their fans would read under the BMC's lower critical RPM. The failsafe can be set up to 90 °C.

When the controller hands a Supermicro back, the BMC gets the fan mode it had before (Standard, Optimal or HeavyIO), read once and kept in the data folder. On docker stop every server is released at the same time; the example compose file gives it 60 s (stop_grace_period), where Docker's default is 10 s.

If the controller itself stops. A control loop that stops turning for 3 minutes trips a watchdog: every fan goes back to its BMC and the process exits, so Docker's restart policy (restart: unless-stopped) starts a fresh one. The image's health check reads /livez, which follows the control loops and not the BMCs. What no process can cover is its own sudden death (kill -9, out of memory, Docker gone): the BMC then keeps the last manual speed. For that, run scripts/fan-guard.sh from root's cron every minute. It finds the Fan Control container by its image, and when it has not been running healthy for two minutes in a row (or Docker itself is down) it hands the fans back to the BMC: Dell and Supermicro with ipmitool, HPE iLO 4 unlocked over SSH. A container that was removed on purpose is left alone.

* * * * * /root/docker/fan-guard.sh >> /var/log/fan-guard.log 2>&1

It reads the servers from the .env next to it (chmod 600; it refuses one others can write): GUARD_SERVERS="R420 X11", then R420_HOST, R420_USERNAME, R420_PASSWORD and R420_DRIVER (dell, supermicro or ilo4-unlocked) for each. A single Dell server only needs the IDRAC_HOST, IDRAC_USERNAME and IDRAC_PASSWORD the compose file already uses.

Dry run decides and logs what it would send ("Dry run: would set fans to 25%"), but leaves the fans to the BMC. Use it to try a new server type or a new curve.

Smoothing and quiet hours

Ramp-down delay: fans speed up at once but slow down only after the lower speed has been asked for during the whole delay. It never runs the fans slower than the curve. Smart mode uses it the same way.

Quiet hours cap the speed between two times of day, for example 23:00 to 07:00 at 25 %. Protection still applies at any hour.

Schedule: up to 8 profiles by day and time, each with a speed cap, a smart mode target, or both. For example Weekend, Saturday and Sunday all day, at most 30 %; or Office hours, Monday to Friday 09:00 to 18:00, smart target 55 °C. A profile from 22:00 to 06:00 runs into the next morning; 00:00 to 00:00 is the whole day. When several are in force, the lowest cap and the lowest target win, together with quiet hours.

A starting point

For a quiet homelab server with Xeon E5 processors, the Quiet preset (35 °C → 12 %, 45 → 15, 55 → 22, 62 → 35, 68 → 55) with a 72 °C failsafe, or Smart with a 60 °C target. Some BMCs raise fan alarms below about 10 %. With third-party PCIe cards installed, stay at 15 % or above, and on Dell leave the third-party PCIe cooling response On.

Per vendor. Dell gets one IPMI command for all fans; some 11th-generation servers refuse it, and the controller then finds the fans they accept and sets them one by one. Supermicro is switched to Full fan mode once, then both zones are set; it goes back to Optimal when released. An unlocked iLO 4 gets a cap on every fan over SSH (fan p N max), so its own curve still runs underneath; releasing removes the cap.

Alerts

Open Alerts in the sidebar and paste a Discord webhook (Server Settings → Integrations → Webhooks → Copy Webhook URL). Everything else is optional: bot name, avatar, footer, a colour per level, mentions (nobody, @here, @everyone, a role or a user, only for the levels you choose), a cooldown, and which events to send, each with its own title and message. A live preview shows the result and Send test posts it before you save. Text that comes from a BMC can never ping anyone.

Event Level Sent when
Failsafe reached warning A limit trips and the BMC takes over
Failsafe cleared resolved Manual control resumes
Running hot warning The CPU passes the "running hot" temperature (off by default)
BMC unreachable error Readings fail
Fan command refused error The BMC rejects a fan command
Back to normal resolved The BMC answers and accepts commands again
Controller error error The control loop hits an unexpected error
Failsafe lasting error The BMC has held the fans for longer than the set time (10 min by default)
Fan failed error A fan stops while the others spin, or the BMC reports it failed (two readings in a row)
Fan commands ignored error The speed moved by 20 points or more, and 30 s later the RPM had not followed
Room running hot warning The inlet air passes its warning temperature (35 °C by default)
Settings changed info Someone applies new settings (off by default)
Controller started info The container starts (off by default)
Status report info On a schedule (off by default)

Placeholders: {server} {host} {model} {cpu} {speed} {mode} {reason} {error} {failsafe} {threshold} {interval} {time}; status reports add {period} {cpu_min} {cpu_avg} {cpu_max} {speed_avg} {power_avg} {dell_pct}.

The status report is one card per server: CPU, fans and power now, minimum, average and maximum over the period, air temperatures, time under automatic control, trend lines and the latest events. By default the same message is edited each time, so the channel holds one live status card.

The alerts page: every event, its text, and a live preview

Discord status report

ntfy, Gotify and any webhook. Under Other channels, the same events and texts go out as plain text: to an ntfy topic (https://ntfy.sh/my-topic, with an access token if the topic is protected), to a Gotify application, or as JSON to any URL (event, level, title, message, server, time and values), which Home Assistant, n8n and most automation tools take as is. Each has its own Send test. The status card stays on Discord only.

Integrations

Each has its own page in the sidebar, with the snippets filled in for your setup.

Prometheus: create a metrics token on the Prometheus page (or set METRICS_TOKEN); the page shows the scrape job to paste and the live /metrics output.

scrape_configs:
  - job_name: fan-control
    authorization:
      credentials: <metrics token>
    static_configs:
      - targets: ["<docker-host>:8080"]
Metric Labels
fanctl_up, fanctl_power_on, fanctl_bmc_control, fanctl_failsafe_active server, name, driver
fanctl_cpu_temperature_celsius, fanctl_inlet_temperature_celsius, fanctl_exhaust_temperature_celsius server, name, driver
fanctl_fan_speed_percent, fanctl_power_watts, fanctl_last_update_timestamp_seconds server, name, driver
fanctl_temperature_celsius ... sensor, entity
fanctl_fan_rpm, fanctl_fan_percent ... fan

Alert rules: web/prometheus-alerts.yml, also on the Prometheus page, covers Fan Control itself being down, a stalled control loop, an unreachable BMC, a lasting failsafe, a failed fan, a hot CPU and refused fan commands. Counters (fanctl_bmc_errors_total, fanctl_fan_commands_total, fanctl_fan_commands_refused_total, fanctl_failsafe_trips_total, fanctl_alerts_sent_total) and fanctl_loop_last_tick_timestamp_seconds are there for rules of your own.

Grafana: download the dashboard from the Grafana page (or web/grafana.json), then Dashboards → New → Import, and pick your Prometheus data source.

Homarr: on the Homarr page, create a widget token (one per dashboard, so each can be revoked), then:

  1. Choose what widgets may show: status, CPU, fans, power, inlet and exhaust air, the last-hour chart, the server model. The token reads those fields and nothing else: never the BMC address, settings, events or error messages.
  2. Homarr 2.0: download the native widget, import it under Management → Custom Widgets, and give it the widget token as its Bearer credential. Homarr fetches /api/widget itself; the widget has options for the server (or all of them), °C or °F, the chart and the air temperatures.
  3. Any dashboard: the page builds an iFrame address for one server or the whole rack, a theme, a background and the fields to show, with a live preview. Any frame size works: a short one drops the chart first, then the footer.
  4. App tile: /healthz answers 200 while every BMC answers and 503 as soon as one stops.

Embed widget

Something wrong with your hardware?

On a server's page, Diagnostics downloads what its BMC answers, raw (ipmitool sdr, sensor, mc info, or the Redfish chassis, thermal, power and system documents), with what Fan Control made of it, the settings and the recent events. Passwords, the BMC address, serial numbers and network details are left out. Attach it to an issue: it is what's needed to support a BMC nobody has tested yet.

Accounts and security

  • WEB_PASSWORD is the admin account. VIEW_PASSWORD adds a read-only one: everything is visible, nothing can be changed, and the backup can't be downloaded.
  • Changes are written to the server's event log with the account and address that made them.
  • Failed sign-ins are slowed and limited to 5 per address in 10 minutes; one address guessing does not lock out the others. Behind a proxy, set TRUST_PROXY=true so the real address is used.
  • Keep the dashboard on your LAN or VPN. With a reverse proxy on the same host, publish the port on localhost only ("127.0.0.1:8080:8080"), forward to it, and keep the Host header (the default in Nginx Proxy Manager). The session cookie gets the Secure flag when the proxy sends X-Forwarded-Proto: https.

Details, and how to report a vulnerability, are in SECURITY.md.

Backup

The Backup page downloads the servers added in the dashboard, every server's fan settings and the Discord configuration as one JSON file, and imports such a file on this or another machine. Passwords and the webhook are included only when you tick the box; a backup without them restores the settings, but servers have to be added again with their passwords.

Troubleshooting

Use Test connection (Edit on the server's page) to see the BMC's answer without saving anything, and Dry run to watch what the controller would do.

Message Meaning
rsp=0xc1 The firmware does not have the fan commands (Dell iDRAC 9 3.34.34.34 or later): use the Redfish type
rsp=0xd4 The BMC user is not an Administrator
Unable to establish IPMI v2 / RMCP+ session Wrong address or credentials, or IPMI over LAN is off
Redfish ...: HTTP 401 Wrong user name or password
Redfish ...: timed out The BMC is not reachable on HTTPS from the container
SSH: ... (is the iLO firmware unlocked?) The iLO answered, but does not have the fan command: stock firmware
... near its N°C warning threshold A sensor other than the CPU is hot; see the Temperatures table, where each bar marks its threshold
ERROR: cannot write to /data (container log) The data folder is not owned by uid 1000

Upgrading

docker compose pull && docker compose up -d

From 1.x: the image is now ghcr.io/st-devpt/rack-fan-control; change it in your compose file. IDRAC_* variables keep working, with their settings and history. Metrics are renamed from idrac_* to fanctl_*: re-import the Grafana dashboard. The mode called "Dell" is now "Automatic"; saved settings are converted. Sessions from 1.x are signed out once.

From 1.0: the container runs as uid 1000. Give it the data folder once with chown -R 1000:1000 ./data. With IDRAC_HOST=local, the container needs /dev/ipmi0 and root to open it:

    user: "0:0"
    devices:
      - /dev/ipmi0:/dev/ipmi0

Changes are listed in CHANGELOG.md.

Development

python app.py                   # dashboard on http://localhost:8080; add a "Demo server" to try it
python -m unittest              # unit tests: drivers, control, smart mode, safety, alerts, HTTP, i18n, upgrades
ruff check .                    # lint, configured in pyproject.toml
FANCTL_URL=http://localhost:8080 FANCTL_PASSWORD=... python -m unittest discover -s e2e   # browser tests (Playwright)

CI runs all of it on every push: ruff, node --check and a duplicate-name check across each page's scripts, shellcheck, promtool on the alert rules, the unit tests on Python 3.10 to 3.13, then the image itself: its health check, the browser tests (every page, WCAG 2 AA with axe, keyboard and touch layouts, Portuguese), docker stop handing the fans back, and a Trivy scan that fails on any fixable HIGH or CRITICAL vulnerability. Published images carry an SBOM and build provenance; actions are pinned by commit and the base image by digest, kept current by Dependabot.

Python 3.10 or newer, no dependencies. The code is in fanctl/: drivers.py (how each kind of BMC is read and driven), control.py (decisions and smart mode, no I/O), server.py (control loop and server registry), alerts.py (Discord, ntfy, Gotify, webhooks), metrics.py (Prometheus), widgets.py (what widgets may read, the Homarr widget), tokens.py (dashboard tokens), backup.py and web.py (HTTP and sessions); app.py starts it all, with the watchdog. Adding a vendor means a class in drivers.py with read(), diagnose() and, if it can control fans, set_speed() and set_auto(). The web pages are in web/: app.js (router, server page, controls), editor.js (adding servers), alerts.js, integrations.js (Prometheus, Grafana, Homarr, backup) and i18n.js (the Portuguese translation), served with a strict Content-Security-Policy.

License

MIT. Bundled fonts: Archivo and IBM Plex Mono, under the SIL Open Font License (web/fonts/).