Add Documentation For Ethernet IP node #5249
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
Open
sumitshinde-84
wants to merge
6
commits into
main
Choose a base branch
from
ethernet-ip-documentation
base: main
Could not load branches
Branch not found: {{ refName }}
Loading
Could not load tags
Nothing to show
Loading
Are you sure you want to change the base?
Some commits from the old base branch may be removed from the timeline,
and old review comments may become outdated.
Open
Changes from 4 commits
Commits
Show all changes
6 commits
Select commit
Hold shift + click to select a range
7f0351a
Add Documentation For Ethernet IP node
sumitshinde-84 c556e48
Update notes
sumitshinde-84 c1952e3
Update and rename ethernet-ip.md to cip-suite.md
sumitshinde-84 0c1fbf7
Merge branch 'main' into ethernet-ip-documentation
sumitshinde-84 b6aa882
Update src/node-red/flowfuse/edge/cip-suite.md
sumitshinde-84 e2700ef
Merge branch 'main' into ethernet-ip-documentation
sumitshinde-84 File filter
Filter by extension
Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
There are no files selected for viewing
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
| Original file line number | Diff line number | Diff line change |
|---|---|---|
| @@ -0,0 +1,292 @@ | ||
| --- | ||
| eleventyNavigation: | ||
| key: CIP Suite — EtherNet/IP Node | ||
| parent: Edge | ||
| order: 2 | ||
| meta: | ||
| title: CIP Suite — EtherNet/IP Node | ||
| description: A CIP Suite node for communicating with Rockwell Automation and Allen-Bradley PLCs using the EtherNet/IP (Ethernet Industrial Protocol) protocol. | ||
| --- | ||
|
|
||
| # {{ meta.title }} | ||
|
|
||
| A CIP Suite node for communicating with Rockwell Automation and Allen-Bradley PLCs using the EtherNet/IP (Ethernet Industrial Protocol) protocol. | ||
|
|
||
| ## Overview | ||
|
|
||
| This node provides a robust interface for connecting FlowFuse flows to industrial control systems, specifically Rockwell Automation and Allen-Bradley programmable logic controllers (PLCs). It wraps the [st-ethernet-ip](https://www.npmjs.com/package/st-ethernet-ip) library to enable real-time tag monitoring and data collection from industrial automation equipment. | ||
|
|
||
| {% note %} | ||
| The CIP Suite EtherNet/IP node is not available by default. It is part of the **FlowFuse Edge Certified Nodes** paid add-on. Please contact our sales team at [Contact us](/contact-us/) to learn more or to request access. | ||
| {% endnote %} | ||
|
|
||
| ## What is EtherNet/IP? | ||
|
|
||
| EtherNet/IP (Ethernet Industrial Protocol) is an industrial network protocol that adapts the Common Industrial Protocol (CIP) to standard Ethernet. It's the primary communication protocol used by Rockwell Automation and Allen-Bradley industrial controllers, including: | ||
|
|
||
| - **ControlLogix** PLCs | ||
| - **CompactLogix** PLCs | ||
| - **MicroLogix** PLCs | ||
| - **PowerFlex** Drives | ||
| - **PanelView** HMIs | ||
| - Other Rockwell Automation/Allen-Bradley devices | ||
|
|
||
| ## How It Works with Rockwell/Allen-Bradley Hardware | ||
|
|
||
| This node establishes a client connection to Allen-Bradley PLCs over EtherNet/IP and provides the following capabilities: | ||
|
|
||
| ### 1. **Controller Discovery** | ||
| When connecting, the node automatically: | ||
| - Reads controller properties (model, serial number, firmware version) | ||
| - Discovers available tags in the controller | ||
| - Retrieves controller time and status | ||
|
|
||
| ### 2. **Tag Subscription** | ||
| The node subscribes to specific tags (variables) in the PLC and monitors them for changes: | ||
| - **BOOL** tags (Boolean/Digital I/O) | ||
| - **DINT** tags (Double Integer/32-bit integers) | ||
| - **REAL** tags (Floating-point values) | ||
| - **STRING** tags (Text data) | ||
| - **Custom data types** (UDTs) | ||
|
|
||
| ### 3. **Real-Time Monitoring** | ||
| - Polls the PLC at a configurable scan rate (50ms to 36000s) | ||
| - Emits messages only when tag values change | ||
| - Maintains a cache of current tag values | ||
| - Handles Allen-Bradley string encoding (82-character strings with 4-byte length prefix) | ||
|
|
||
| ### 4. **Connection Management** | ||
| - Automatic connection lifecycle management | ||
| - Proper cleanup on deployment or shutdown | ||
| - Error handling and status reporting | ||
| - Support for different slot configurations (backplane addressing) | ||
|
|
||
| ## Installation | ||
|
|
||
| Because this node is part of the **FlowFuse Edge Certified Nodes** add-on, make sure your account has access before installing. Contact our [sales team](/contact-us/) if you don't. | ||
|
|
||
| {% note %} | ||
| Existing devices and hosted instances will not see newly added nodes until they are restarted. Restart any instance you plan to install nodes on so it picks up the updated catalogue. | ||
| {% endnote %} | ||
|
|
||
| ### Install via the Palette Manager (recommended) | ||
|
|
||
| 1. Open the **Palette Manager** from the top-right menu in the FlowFuse editor. | ||
| 2. Switch to the **Install** tab. | ||
| 3. Search for the **FlowFuse Edge Certified Nodes** collection. | ||
| 4. Locate `@flowfuse-certified-nodes/cip-suite` and click **Install**. | ||
|
|
||
| ### Install via npm | ||
|
|
||
| If you manage your palette from the command line, install the package directly: | ||
|
|
||
| ```bash | ||
| npm install @flowfuse-certified-nodes/cip-suite | ||
| ``` | ||
|
|
||
| ## Usage | ||
|
|
||
| ### Input Message Format | ||
|
|
||
| Send a message with the following payload structure to initiate a PLC connection: | ||
|
|
||
| ```json | ||
| { | ||
| "address": "192.168.1.100", | ||
| "slot": 0, | ||
| "scanRate": 500, | ||
| "tagConfig": [ | ||
| { | ||
| "scope": "", | ||
| "tags": [ | ||
| { | ||
| "tagName": "ProductionCount", | ||
| "tagType": "DINT" | ||
| }, | ||
| { | ||
| "tagName": "ConveyorRunning", | ||
| "tagType": "BOOL" | ||
| }, | ||
| { | ||
| "tagName": "Temperature", | ||
| "tagType": "REAL" | ||
| }, | ||
| { | ||
| "tagName": "PartNumber", | ||
| "tagType": "STRING" | ||
| } | ||
| ] | ||
| } | ||
| ] | ||
| } | ||
| ``` | ||
|
|
||
| #### Configuration Parameters | ||
|
|
||
| - **address**: IP address of the PLC (required) | ||
| - **slot**: Backplane slot number where the processor is located (typically 0 for CompactLogix, varies for ControlLogix) | ||
| - **scanRate**: Polling interval in milliseconds (50-36000000ms) | ||
| - **tagConfig**: Array of tag scopes containing tags to monitor | ||
| - **scope**: Tag scope in the controller (empty string for controller-scoped tags) | ||
| - **tags**: Array of tag objects | ||
| - **tagName**: Name of the tag in the PLC program | ||
| - **tagType**: Data type (BOOL, DINT, REAL, STRING, etc.) | ||
|
|
||
| ### Outputs | ||
|
|
||
| #### Output 1: PLC Data | ||
|
|
||
| Emits updated tag values when changes are detected: | ||
|
|
||
| ```json | ||
| { | ||
| "payload": { | ||
| "ProductionCount": 1250, | ||
| "ConveyorRunning": true, | ||
| "Temperature": 72.5, | ||
| "PartNumber": "ABC-123-XYZ" | ||
| }, | ||
| "changedTagName": "ProductionCount", | ||
| "changedTagValue": 1250 | ||
| } | ||
| ``` | ||
|
|
||
| #### Output 2: Debug/Metadata | ||
|
|
||
| Provides diagnostic information and PLC metadata: | ||
|
|
||
| ```json | ||
| { | ||
| "payload": { | ||
| "category": "plcProps", | ||
| "value": { | ||
| "name": "CompactLogix Controller", | ||
| "serial": "12345678", | ||
| "slot": 0, | ||
| "version": "31.011" | ||
| } | ||
| } | ||
| } | ||
| ``` | ||
|
|
||
| **Categories:** | ||
| - `plcConfig`: Echoes the input configuration | ||
| - `plcProps`: Controller properties (model, serial, etc.) | ||
| - `plcTime`: Controller clock time | ||
| - `plcTags`: Complete list of available tags | ||
| - `debug`: Diagnostic messages | ||
| - `error`: Error information | ||
|
|
||
| ### Connection States | ||
|
|
||
| Monitor the node status to track connection health: | ||
|
|
||
| | State | Color | Meaning | | ||
| |-------|-------|---------| | ||
| | connecting | blue | Initiating connection to PLC | | ||
| | reading props | blue | Reading controller properties | | ||
| | discovering tags | blue | Scanning for available tags | | ||
| | connected | green | Active and monitoring tags | | ||
| | closing | gray | Shutting down connection | | ||
| | closed | red | Disconnected and idle | | ||
| | warn - end | yellow | PLC terminated connection | | ||
| | warn - closed | yellow | Connection closed | | ||
| | error - config | red | Invalid input message | | ||
| | error - connect | red | Cannot reach PLC | | ||
| | error - prop read | red | Cannot read properties | | ||
| | error - tag discovery | red | Cannot read tag list | | ||
| | error - scan | red | Error during tag scanning | | ||
| | error - disconnect | red | Error during shutdown | | ||
| | error - controller | red | Incompatible controller type | | ||
|
|
||
| ## Example Flow | ||
|
|
||
| ```json | ||
| [ | ||
| { | ||
| "id": "inject1", | ||
| "type": "inject", | ||
| "name": "Connect to PLC", | ||
| "topic": "", | ||
| "payload": "{\"address\":\"192.168.1.100\",\"slot\":0,\"scanRate\":500,\"tagConfig\":[{\"scope\":\"\",\"tags\":[{\"tagName\":\"Tag1\",\"tagType\":\"DINT\"}]}]}", | ||
| "payloadType": "json", | ||
| "wires": [["plcNode"]] | ||
| }, | ||
| { | ||
| "id": "plcNode", | ||
| "type": "eth-ip", | ||
| "name": "Production Line PLC", | ||
| "wires": [["output"], ["debug"]] | ||
| } | ||
| ] | ||
| ``` | ||
|
|
||
| ## Best Practices | ||
|
|
||
| ### Connection Management | ||
| - Any new input message will close the existing connection and establish a new one | ||
| - Use a **status node** to monitor connection health and implement retry logic | ||
| - Handle reconnection logic externally to the node | ||
|
|
||
| ### Network Configuration | ||
| - Ensure your FlowFuse instance can reach the PLC IP address | ||
| - Configure firewall rules to allow TCP port 44818 (EtherNet/IP) | ||
| - Use static IP addresses for PLCs in production environments | ||
|
|
||
| ### Tag Selection | ||
| - Only subscribe to tags you need to minimize network traffic | ||
| - Use appropriate scan rates based on how quickly data changes | ||
| - Faster scan rates increase CPU and network load | ||
|
|
||
| ### Error Handling | ||
| - Connect a **catch node** to handle errors gracefully | ||
| - Monitor the debug output for diagnostic information | ||
| - Implement reconnection strategies for production reliability | ||
|
|
||
| ## Compatibility | ||
|
|
||
| ### Tested Hardware | ||
| - Allen-Bradley ControlLogix (L7x, L8x series) | ||
| - Allen-Bradley CompactLogix (L1x, L2x, L3x series) | ||
| - Allen-Bradley MicroLogix (1100, 1400, 1500 series) | ||
|
|
||
| ### Supported Data Types | ||
| - BOOL (Boolean) | ||
| - SINT (Short Integer) | ||
| - INT (Integer) | ||
| - DINT (Double Integer) | ||
| - REAL (Floating Point) | ||
| - STRING (82-character Allen-Bradley strings) | ||
| - Custom UDTs (User Defined Types) | ||
|
|
||
| ## Troubleshooting | ||
|
|
||
| ### Cannot Connect to PLC | ||
| - Verify IP address and network connectivity (ping test) | ||
| - Check slot number matches your controller configuration | ||
| - Ensure PLC firmware supports EtherNet/IP messaging | ||
| - Verify firewall settings allow TCP 44818 | ||
|
|
||
| ### Tags Not Updating | ||
| - Confirm tag names match exactly (case-sensitive) | ||
| - Verify tag scope is correct | ||
| - Check scan rate isn't too slow for your application | ||
| - Ensure tags exist in the controller | ||
|
|
||
| ### Connection Drops Frequently | ||
| - Reduce scan rate to decrease network load | ||
| - Check network stability and switch configuration | ||
| - Verify PLC isn't overloaded with connections | ||
| - Consider using unconnected messaging for multiple clients | ||
|
|
||
| ## Technical Details | ||
|
|
||
| This node uses **unconnected messaging** mode by default with a 5064ms timeout, which: | ||
| - Reduces timeout issues with multiple clients | ||
| - Works better in high-latency networks | ||
| - Allows multiple nodes to connect to the same PLC | ||
|
|
||
| String handling automatically decodes Allen-Bradley's proprietary format: | ||
| - First 4 bytes contain Little-Endian INT32 length | ||
| - Remaining bytes contain ASCII character data | ||
| - Maximum length of 82 characters | ||
Add this suggestion to a batch that can be applied as a single commit.
This suggestion is invalid because no changes were made to the code.
Suggestions cannot be applied while the pull request is closed.
Suggestions cannot be applied while viewing a subset of changes.
Only one suggestion per line can be applied in a batch.
Add this suggestion to a batch that can be applied as a single commit.
Applying suggestions on deleted lines is not supported.
You must change the existing code in this line in order to create a valid suggestion.
Outdated suggestions cannot be applied.
This suggestion has been applied or marked resolved.
Suggestions cannot be applied from pending reviews.
Suggestions cannot be applied on multi-line comments.
Suggestions cannot be applied while the pull request is queued to merge.
Suggestion cannot be applied right now. Please check back later.
Uh oh!
There was an error while loading. Please reload this page.