These are some common issues which others have encountered whilst using the service. For debugging tools and features, see the Debugging guide.
The service works out which Chromedriver to use from your app's Electron version, which it reads from the electron (or electron-nightly) dependency in the package.json nearest your rootDir. This error means it found no such dependency.
The usual cause is testing an app built elsewhere — a downloaded release artifact, or a build produced by a separate CI job — so the tests have no local Electron install even though appBinaryPath points at a perfectly good app.
Any one of these resolves it:
- Install
electronas adevDependencyin the project being tested. - Set the
browserVersioncapability to the Electron version under test — see Chromedriver Configuration. - Set
wdio:chromedriverOptions.binaryto a Chromedriver you provide.
The Electron version was found, but the service could not map it to a Chromium version, so it cannot select a matching Chromedriver. Installing Electron will not help — it is already installed.
The mapping comes from https://electronjs.org/headers/index.json, falling back to the bundled electron-to-chromium data when that request fails. It comes up short when:
- the build is a fork whose version is not a published Electron release;
- the build is a nightly and the online lookup is unavailable — the bundled fallback contains no nightly versions;
- the Electron release is newer than the bundled data and the online lookup is unavailable.
Resolve it by pinning Chromedriver yourself:
-
Set
wdio:chromedriverOptions.binaryto a Chromedriver matching your app's Chromium version. -
Or set the
browserVersioncapability to the Chromium version your Electron build uses. You can read that from the app itself:$ ELECTRON_RUN_AS_NODE=1 /path/to/your/app -p "process.versions.chrome" 150.0.7871.129
See Chromedriver Configuration for where these belong in your config.
This warning appears when your Electron app has the EnableNodeCliInspectArguments fuse explicitly disabled. The CDP (Chrome DevTools Protocol) bridge relies on the --inspect flag to connect to Electron's main process, so when this fuse is disabled, the service cannot provide access to the main process APIs.
When this fuse is disabled:
- ❌
browser.electron.execute()- main process API access will not work - ❌
browser.electron.mock()- mocking main process APIs will not work - ❌ Main process log capture will not work (see Debugging - Log Capture Requirements)
- ✅ Renderer process testing continues to work normally
- ✅ Renderer process log capture continues to work (uses Puppeteer, not CDP bridge)
- ✅ Service initialization continues normally - no crashes or failures
- ✅ Clear error messages when attempting to use disabled APIs
Enable the fuse in your test builds. If you're disabling this fuse for production (which is good security practice), use conditional configuration:
import { flipFuses, FuseVersion, FuseV1Options } from '@electron/fuses';
await flipFuses(require('electron'), {
version: FuseVersion.V1,
[FuseV1Options.EnableNodeCliInspectArguments]: process.env.BUILD_FOR_TESTS === 'true',
// ... other fuses
});Then build with the environment variable, e.g.:
BUILD_FOR_TESTS=true npm run build # for testing
npm run build # for productionSee: Electron Fuses Documentation
The EnableNodeCliInspectArguments fuse is enabled, but the service could not reach the app's Node inspector. The service logs the connection error when the session starts, and every browser.electron call that needs the bridge throws it, with a message starting CDP bridge could not connect to the main process, API is disabled:. Main process log capture is off for that session. Tests that don't use those APIs still run.
Check that:
- The app is still running after it starts. If it exits or crashes during startup, its inspector goes with it.
- The inspector has time to start. On a slow machine, raise
cdpBridgeTimeout.
This is a Chromium error which may appear when using Docker or CI. Most of the "fixes" discussed online are based around passing different combinations of args to Chromium - you can set these via appArgs, though in most cases running under a virtual display such as Xvfb has proven more effective.
WebdriverIO 9.19.1+ starts a virtual display on Linux when none is set; older versions need xvfb-run or xvfb-maybe. WebdriverIO v10 starts Weston if it's installed and Xvfb otherwise, and the service is tested on both. See Headless & Display Servers.
Failed to create session. session not created: probably user data directory is already in use, please specify a unique value for --user-data-dir argument, or don't use --user-data-dir
This is another obscure Chromium error which, despite the message, is usually not fixed by providing a unique --user-data-dir value. In the Electron context this usually occurs when the Electron app crashes during or shortly after initialization. WDIO / ChromeDriver attempts to reconnect, starting a new electron instance, which attempts to use the same user-data-dir path. Whilst there may be other causes, on Linux this is often fixed with a virtual display, as described above.
See this issue for more details. This is caused by AppArmor restrictions on unprivileged user namespaces.
The service can automatically create and install a custom AppArmor profile for your Electron binary. Enable this feature by setting the apparmorAutoInstall option:
export const config = {
// ...
services: [
[
'electron',
{
apparmorAutoInstall: 'sudo', // or true if running as root
},
],
],
// OR configure it per capability:
capabilities: [
{
browserName: 'electron',
'wdio:electronServiceOptions': {
apparmorAutoInstall: 'sudo',
},
},
],
};'sudo': Install if root or via non-interactive sudo (sudo -n) if availabletrue: Install only if running as root (no sudo)false(default): Never install; warn and continue without AppArmor profile
Manual AppArmor workaround: Run sysctl -w kernel.apparmor_restrict_unprivileged_userns=0 before running your tests. This command requires root privileges; if necessary, run it as the root user or use the sudo command.
Still applies in v10. The package was renamed from
wdio-electron-serviceto@wdio/electron-service, but the import-time initialization order didn't change — the same workaround is needed.
This error occurs when importing the browser object directly at the top level of test files:
// ❌ This may cause "TypeError: logger is not a function"
import { browser } from '@wdio/electron-service';
describe('My Tests', () => {
it('should work', async () => {
await browser.electron.execute(/* ... */);
});
});The service's internal logger and other dependencies aren't fully initialized when the browser object is imported during the test file loading phase, before WebDriverIO services have completed their initialization.
The solution is to use dynamic import within a before hook to ensure the service is fully initialized:
// ✅ Correct approach - dynamic import in before hook
import type { Mock } from '@vitest/spy';
import { $, expect } from '@wdio/globals';
import type { browser as WdioBrowser } from '@wdio/electron-service';
let browser: typeof WdioBrowser;
describe('My Tests', () => {
before(async () => {
({ browser } = await import('@wdio/electron-service'));
});
it('should work', async () => {
await browser.electron.execute(/* ... */);
});
});Note for Service Contributors: If you're working within the desktop-mobile repository itself, you can use pnpm overrides to link to the workspace version:
{
"pnpm": {
"overrides": {
"@wdio/electron-service": "workspace:*"
}
}
}This allows direct imports to work reliably within the service's own repository, but this approach only applies when developing the service itself.