Description
I have set the following:
ebusd --foreground --mqtthost=core-mosquitto --mqttport=1883 --mqttuser=*** --mqttpass=*** --scanconfig --mqttjson --configpath=/config/ebusd/en --accesslevel=* --mqttint=/etc/ebusd/mqtt-hassio.cfg --mqttvar=filter-direction=r|u|^w,filter-name=status|temp|yield|power|runtime|hours|starts|curve|^load$|^party$|sensor|pressure|press|mode|state|PowerValue|Temp|Water|SetMode|powervalue --mqtttopic=ebusd --device=ens:x.x.x.x:9999 --log=all:notice --log=bus:notice
and see the following in MQTT Explorer:
But in Devices - MQTT I don't see it.
Actual behavior
Dont see PowerValue in Devices - MQTT
Expected behavior
I expect to see the PowerValue in Devices - MQTT
ebusd version
26.1
ebusd arguments
ebusd --foreground --mqtthost=core-mosquitto --mqttport=1883 --mqttuser=**** --mqttpass=*** --scanconfig --mqttjson --configpath=/config/ebusd/en --accesslevel=* --mqttint=/etc/ebusd/mqtt-hassio.cfg --mqttvar=filter-direction=r|u|^w,filter-name=status|temp|yield|power|runtime|hours|starts|curve|^load$|^party$|sensor|pressure|press|mode|state|PowerValue|Temp|Water|SetMode|powervalue --mqtttopic=ebusd --device=ens:x.x.x.x:9999 --log=all:notice --log=bus:notice
Operating system
Debian 13 (Trixie) / Ubuntu 24-25 / Raspberry Pi OS 13
CPU architecture
x64
Dockerized
latest
Hardware interface
Adapter Shield v5/C6/Stick via USB
Related integration
MQTT Home Assistant via mqtt-hassio.cfg
Logs
2026-03-02 18:31:46.803 [device notice] transport opened
2026-03-02 18:31:46.805 [main notice] ebusd 26.1.26.1 started with broadcast scan on device: 10.20.26.64:9999, TCP, enhanced
2026-03-02 18:31:46.805 [bus notice] bus started with own address 31/36
2026-03-02 18:31:46.806 [device notice] reset, supports info
2026-03-02 18:31:46.809 [bus notice] signal acquired
2026-03-02 18:31:46.809 [device notice] extra info: firmware 1.1[6208].1[6208], jumpers 0x0b
2026-03-02 18:31:46.813 [mqtt notice] connection established
2026-03-02 18:31:56.806 [main notice] starting initial broadcast scan
2026-03-02 18:31:56.915 [update notice] sent write Broadcast Queryexistence QQ=31:
2026-03-02 18:32:21.969 [bus notice] new master 00, master count 2
2026-03-02 18:32:27.119 [main error] scan config 05: ERR: read timeout
2026-03-02 18:32:37.175 [bus notice] new master 03, master count 3
2026-03-02 18:32:39.335 [bus notice] scan 08: ;Vaillant;BAI00;0200;7503
2026-03-02 18:32:39.335 [update notice] store 08 ident: done
2026-03-02 18:32:39.335 [update notice] sent scan-read scan.08 QQ=31: Vaillant;BAI00;0200;7503
2026-03-02 18:32:39.335 [bus notice] scan 08: ;Vaillant;BAI00;0200;7503
2026-03-02 18:32:39.336 [main notice] read common config file vaillant/broadcast.csv
2026-03-02 18:32:39.336 [main notice] read common config file vaillant/general.csv
2026-03-02 18:32:39.336 [main notice] read common config file vaillant/scan.csv
2026-03-02 18:32:39.336 [main notice] read scan config file vaillant/08.bai.csv for ID "bai00", SW0200, HW7503
2026-03-02 18:32:39.508 [update notice] sent scan-read Scan.08 Id QQ=31:
2026-03-02 18:32:39.682 [update notice] sent scan-read Scan.08 Id QQ=31:
2026-03-02 18:32:39.853 [update notice] sent scan-read Scan.08 Id QQ=31:
2026-03-02 18:32:40.004 [bus notice] max. symbols per second: 107
2026-03-02 18:32:40.033 [update notice] sent scan-read Scan.08 Id QQ=31: 21;25;12;0010023673;3130;316592;N0
2026-03-02 18:32:40.037 [main notice] found messages: 236 (3 conditional on 35 conditions, 0 poll, 16 update)
2026-03-02 18:32:40.200 [update notice] sent scan-read Scan.08 Id QQ=31: 21;25;12;0010023673;3130;316592;N0
2026-03-02 18:32:40.368 [update notice] sent scan-read Scan.08 Id QQ=31: 21;25;12;0010023673;3130;316592;N0
2026-03-02 18:32:40.552 [update notice] sent scan-read Scan.08 Id QQ=31: 21;25;12;0010023673;3130;316592;N0
2026-03-02 18:32:40.729 [update notice] sent scan-read Scan.08 Id QQ=31: 21;25;12;0010023673;3130;316592;N0
2026-03-02 18:32:40.729 [bus notice] scan 08: ;21;25;12;0010023673;3130;316592;N0
2026-03-02 18:32:50.902 [update notice] sent poll-read bai CounterStartattempts1 QQ=31: 0
2026-03-02 18:32:56.182 [update notice] sent poll-read bai CounterStartattempts2 QQ=31: 0
2026-03-02 18:33:02.168 [update notice] sent poll-read bai CounterStartAttempts3 QQ=31: 0
2026-03-02 18:33:08.196 [update notice] sent poll-read bai CounterStartAttempts4 QQ=31: 0
2026-03-02 18:33:12.914 [main error] scan config 05: ERR: read timeout
2026-03-02 18:33:14.158 [update notice] sent poll-read bai DcfState QQ=31: nosignal
2026-03-02 18:33:14.916 [main notice] scan completed 1 time(s), check again
2026-03-02 18:33:20.159 [update notice] sent poll-read bai DeactivationsTemplimiter QQ=31: 0
2026-03-02 18:33:26.174 [update notice] sent poll-read bai DisplayMode QQ=31: 2
2026-03-02 18:33:32.186 [update notice] sent poll-read bai Expertlevel_ReturnTemp QQ=31: -1.81;cutoff
2026-03-02 18:33:38.184 [update error] unable to parse poll-read bai ExternalFlowTempDesired from 3108b509030d2500 / 00: ERR: invalid position
2026-03-02 18:33:39.958 [mqtt error] decode bai ExternalFlowTempDesired: ERR: invalid position
2026-03-02 18:33:44.165 [update error] unable to parse poll-read bai ExtFlowTempDesiredMin from 3108b509030d6e04 / 00: ERR: invalid position
2026-03-02 18:33:49.974 [mqtt error] decode bai ExtFlowTempDesiredMin: ERR: invalid position
2026-03-02 18:33:50.189 [update notice] sent poll-read bai FanHours QQ=31: -
2026-03-02 18:33:56.136 [update notice] sent poll-read bai FanStarts QQ=31: -
2026-03-02 18:34:02.224 [bus error] poll bai FlowTemp failed: ERR: read timeout
2026-03-02 18:34:08.191 [update notice] sent poll-read bai FlowTempDesired QQ=31: 25.00
2026-03-02 18:34:14.150 [update notice] sent poll-read bai FlowTempMax QQ=31: 0.00
2026-03-02 18:34:20.164 [update notice] sent poll-read bai HcHours QQ=31: 0
2026-03-02 18:34:25.103 [main error] scan config 05: ERR: read timeout
2026-03-02 18:34:26.210 [update error] unable to parse poll-read bai HcPumpMode from 3108b509030d4904 / 00: ERR: invalid position
2026-03-02 18:34:27.105 [main notice] scan completed 2 time(s), check again
2026-03-02 18:34:27.111 [mqtt error] decode bai HcPumpMode: ERR: invalid position
2026-03-02 18:34:32.184 [update notice] sent poll-read bai HcPumpStarts QQ=31: -
2026-03-02 18:34:38.175 [update notice] sent poll-read bai HcStarts QQ=31: 0
2026-03-02 18:34:44.170 [update notice] sent poll-read bai HcUnderHundredStarts QQ=31: 0
2026-03-02 18:34:47.231 [device notice] extra info: ID ccba97f8e604480200
2026-03-02 18:34:47.331 [main notice] update check: OK, device firmware 1[6301] available, broadcast.csv: different version available, memory.csv: different version available, vaillant/08.bai.csv: different version available, vaillant/bai.308523.inc: different version available, vaillant/broadcast.csv: different version available, vaillant/general.csv: different version available, vaillant/scan.csv: different version available
2026-03-02 18:34:50.191 [update error] unable to parse poll-read bai HoursTillService from 3108b509030d2004 / 00: ERR: invalid position
2026-03-02 18:34:52.345 [mqtt error] decode bai HoursTillService: ERR: invalid position
2026-03-02 18:34:56.156 [update notice] sent poll-read bai HwcHours QQ=31: 0
2026-03-02 18:35:00.357 [update notice] sent update-write bai SetModeOverride QQ=31: off;25.0;0.0;0;0;0;0;0;0;1
2026-03-02 18:35:00.357 [mqtt notice] write bai SetModeOverride: 1;25.0;0;0;0;0;0;0;0;1;0;0
2026-03-02 18:35:02.180 [update error] unable to parse poll-read bai HwcPostrunTime from 3108b509030d1104 / 00: ERR: invalid position
2026-03-02 18:35:07.370 [mqtt error] decode bai HwcPostrunTime: ERR: invalid position
2026-03-02 18:35:08.164 [update notice] sent poll-read bai HwcStarts QQ=31: 0
2026-03-02 18:35:14.847 [bus error] poll bai HwcTemp failed: ERR: read timeout
2026-03-02 18:35:20.158 [update notice] sent poll-read bai HwcTempDesired QQ=31: 15.00
2026-03-02 18:35:26.171 [update error] unable to parse poll-read bai HwcTempMax from 3108b509030d4304 / 00: ERR: invalid position
2026-03-02 18:35:27.417 [mqtt error] decode bai HwcTempMax: ERR: invalid position
2026-03-02 18:35:32.163 [update notice] sent poll-read bai HwcUnderHundredStarts QQ=31: 0
2026-03-02 18:35:37.721 [main error] scan config 05: ERR: read timeout
2026-03-02 18:35:38.252 [update notice] sent poll-read bai HwcWaterflow QQ=31: 0.00
2026-03-02 18:35:39.722 [main notice] scan completed 3 time(s), check again
2026-03-02 18:35:44.164 [update notice] sent poll-read bai HwcWaterflowMax QQ=31: 0.00
2026-03-02 18:35:50.174 [update notice] sent poll-read bai Maintenancedata_HwcTempMax QQ=31: 0.00
2026-03-02 18:35:56.181 [update notice] sent poll-read bai OutdoorstempSensor QQ=31: -60.44;cutoff
2026-03-02 18:36:02.205 [update notice] sent poll-read bai PowerValue QQ=31: 11 02 64 0e 64 0e
2026-03-02 18:36:08.174 [update notice] sent poll-read bai PrVortexFlowSensorValue QQ=31: -1
2026-03-02 18:36:14.185 [update notice] sent poll-read bai PumpHours QQ=31: -
2026-03-02 18:36:20.147 [update notice] sent poll-read bai PumpPower QQ=31: 0
2026-03-02 18:36:26.143 [update notice] sent poll-read bai PumpPowerDesired QQ=31: auto
2026-03-02 18:36:32.194 [update notice] sent poll-read bai ReturnTemp QQ=31: 0.00;-;ok
2026-03-02 18:36:38.185 [update notice] sent poll-read bai ReturnTempMax QQ=31: 0.00
2026-03-02 18:36:44.155 [update error] unable to parse poll-read bai SecondPumpMode from 3108b509030d0b04 / 00: ERR: invalid position
2026-03-02 18:36:49.914 [main error] scan config 05: ERR: read timeout
2026-03-02 18:36:49.915 [mqtt error] decode bai SecondPumpMode: ERR: invalid position
2026-03-02 18:36:50.459 [update notice] sent poll-read bai SHEMaxFlowTemp QQ=31: -0.06
2026-03-02 18:36:51.916 [main notice] scan completed 4 time(s), check again
2026-03-02 18:36:56.166 [update notice] sent poll-read bai Statenumber QQ=31: 31
2026-03-02 18:37:02.170 [update notice] sent poll-read bai Status01 QQ=31: 18.0;0.0;-;0.0;-;off
2026-03-02 18:37:08.196 [update notice] sent poll-read bai Status02 QQ=31: auto;50;80.0;70;70.0
2026-03-02 18:37:14.140 [update error] unable to parse poll-read bai Status16 from 3108b5040116 / 00: ERR: invalid position
2026-03-02 18:37:17.010 [mqtt error] decode bai Status16: ERR: invalid position
2026-03-02 18:37:20.177 [update error] unable to parse poll-read bai Status from 3108b5110103 / 00: ERR: invalid position
2026-03-02 18:37:22.017 [mqtt error] decode bai Status: ERR: invalid position
2026-03-02 18:37:26.174 [update notice] sent poll-read bai StorageLoadPumpHours QQ=31: -
2026-03-02 18:37:32.157 [update notice] sent poll-read bai StorageloadPumpStarts QQ=31: -
2026-03-02 18:37:38.188 [update notice] sent poll-read bai StorageTemp QQ=31: -14.94;cutoff
2026-03-02 18:37:44.155 [update notice] sent poll-read bai StorageTempDesired QQ=31: 15.00
2026-03-02 18:37:50.161 [update notice] sent poll-read bai StorageTempMax QQ=31: 0.00
2026-03-02 18:37:56.173 [update notice] sent poll-read bai TempDiffBlock QQ=31: 0
2026-03-02 18:38:02.104 [main error] scan config 05: ERR: read timeout
2026-03-02 18:38:02.653 [update notice] sent poll-read bai TempDiffFailure QQ=31: 0
2026-03-02 18:38:04.106 [main notice] scan completed 5 time(s), check again
2026-03-02 18:38:08.175 [update notice] sent poll-read bai TempGradientFailure QQ=31: 0
2026-03-02 18:38:14.174 [update notice] sent poll-read bai Templimiter QQ=31: off
2026-03-02 18:38:20.177 [update notice] sent poll-read bai TemplimiterWithNTC QQ=31: no
2026-03-02 18:38:26.183 [update notice] sent poll-read bai TempMaxDiffExtTFT QQ=31: -0.06
2026-03-02 18:38:32.630 [update error] unable to parse poll-read bai ValveMode from 3108b509030d2a04 / 00: ERR: invalid position
2026-03-02 18:38:34.153 [mqtt error] decode bai ValveMode: ERR: invalid position
2026-03-02 18:38:38.155 [update notice] sent poll-read bai ValveStarts QQ=31: -
2026-03-02 18:38:44.153 [update error] unable to parse poll-read bai VortexFlowSensor from 3108b509030dd500 / 00: ERR: invalid position
2026-03-02 18:38:49.175 [mqtt error] decode bai VortexFlowSensor: ERR: invalid position
2026-03-02 18:38:50.146 [update notice] sent poll-read bai WaterHcFlowMax QQ=31: -
2026-03-02 18:38:56.159 [update notice] sent poll-read bai WaterPressure QQ=31: 1.479;ok
2026-03-02 18:39:02.167 [update notice] sent poll-read bai WaterpressureBranchControlOff QQ=31: on
2026-03-02 18:39:08.174 [update notice] sent poll-read bai WaterpressureMeasureCounter QQ=31: -
2026-03-02 18:39:14.190 [update notice] sent poll-read bai WaterpressureVariantSum QQ=31: -
2026-03-02 18:39:14.361 [main error] scan config 05: ERR: read timeout
2026-03-02 18:39:16.363 [main notice] scan completed 6 time(s), end
2026-03-02 18:39:20.153 [update error] unable to parse poll-read bai WPPostrunTime from 3108b509030df703 / 00: ERR: invalid position
2026-03-02 18:39:21.371 [mqtt error] decode bai WPPostrunTime: ERR: invalid position
2026-03-02 18:39:26.151 [update notice] sent poll-read bai CounterStartattempts1 QQ=31: 0
2026-03-02 18:39:32.185 [update notice] sent poll-read bai CounterStartattempts2 QQ=31: 0
2026-03-02 18:39:38.134 [update notice] sent poll-read bai CounterStartAttempts3 QQ=31: 0
2026-03-02 18:39:44.176 [update notice] sent poll-read bai CounterStartAttempts4 QQ=31: 0
2026-03-02 18:39:50.174 [update notice] sent poll-read bai DcfState QQ=31: nosignal
2026-03-02 18:39:56.173 [update notice] sent poll-read bai DeactivationsTemplimiter QQ=31: 0
2026-03-02 18:40:00.366 [update notice] sent update-write bai SetModeOverride QQ=31: off;25.0;0.0;0;0;0;0;0;0;1
2026-03-02 18:40:00.366 [mqtt notice] write bai SetModeOverride: 1;25.0;0;0;0;0;0;0;0;1;0;0
2026-03-02 18:40:02.164 [update notice] sent poll-read bai DisplayMode QQ=31: 2
2026-03-02 18:40:08.184 [update notice] sent poll-read bai Expertlevel_ReturnTemp QQ=31: -1.81;cutoff
2026-03-02 18:40:14.186 [update error] unable to parse poll-read bai ExternalFlowTempDesired from 3108b509030d2500 / 00: ERR: invalid position
2026-03-02 18:40:16.439 [mqtt error] decode bai ExternalFlowTempDesired: ERR: invalid position
2026-03-02 18:40:20.158 [update error] unable to parse poll-read bai ExtFlowTempDesiredMin from 3108b509030d6e04 / 00: ERR: invalid position
2026-03-02 18:40:21.446 [mqtt error] decode bai ExtFlowTempDesiredMin: ERR: invalid position
2026-03-02 18:40:26.174 [update notice] sent poll-read bai FanHours QQ=31: -
2026-03-02 18:40:32.154 [update notice] sent poll-read bai FanStarts QQ=31: -
Description
I have set the following:
ebusd --foreground --mqtthost=core-mosquitto --mqttport=1883 --mqttuser=*** --mqttpass=*** --scanconfig --mqttjson --configpath=/config/ebusd/en --accesslevel=* --mqttint=/etc/ebusd/mqtt-hassio.cfg --mqttvar=filter-direction=r|u|^w,filter-name=status|temp|yield|power|runtime|hours|starts|curve|^load$|^party$|sensor|pressure|press|mode|state|PowerValue|Temp|Water|SetMode|powervalue --mqtttopic=ebusd --device=ens:x.x.x.x:9999 --log=all:notice --log=bus:notice
and see the following in MQTT Explorer:
But in Devices - MQTT I don't see it.
Actual behavior
Dont see PowerValue in Devices - MQTT
Expected behavior
I expect to see the PowerValue in Devices - MQTT
ebusd version
26.1
ebusd arguments
ebusd --foreground --mqtthost=core-mosquitto --mqttport=1883 --mqttuser=**** --mqttpass=*** --scanconfig --mqttjson --configpath=/config/ebusd/en --accesslevel=* --mqttint=/etc/ebusd/mqtt-hassio.cfg --mqttvar=filter-direction=r|u|^w,filter-name=status|temp|yield|power|runtime|hours|starts|curve|^load$|^party$|sensor|pressure|press|mode|state|PowerValue|Temp|Water|SetMode|powervalue --mqtttopic=ebusd --device=ens:x.x.x.x:9999 --log=all:notice --log=bus:notice
Operating system
Debian 13 (Trixie) / Ubuntu 24-25 / Raspberry Pi OS 13
CPU architecture
x64
Dockerized
latest
Hardware interface
Adapter Shield v5/C6/Stick via USB
Related integration
MQTT Home Assistant via mqtt-hassio.cfg
Logs
2026-03-02 18:31:46.803 [device notice] transport opened
2026-03-02 18:31:46.805 [main notice] ebusd 26.1.26.1 started with broadcast scan on device: 10.20.26.64:9999, TCP, enhanced
2026-03-02 18:31:46.805 [bus notice] bus started with own address 31/36
2026-03-02 18:31:46.806 [device notice] reset, supports info
2026-03-02 18:31:46.809 [bus notice] signal acquired
2026-03-02 18:31:46.809 [device notice] extra info: firmware 1.1[6208].1[6208], jumpers 0x0b
2026-03-02 18:31:46.813 [mqtt notice] connection established
2026-03-02 18:31:56.806 [main notice] starting initial broadcast scan
2026-03-02 18:31:56.915 [update notice] sent write Broadcast Queryexistence QQ=31:
2026-03-02 18:32:21.969 [bus notice] new master 00, master count 2
2026-03-02 18:32:27.119 [main error] scan config 05: ERR: read timeout
2026-03-02 18:32:37.175 [bus notice] new master 03, master count 3
2026-03-02 18:32:39.335 [bus notice] scan 08: ;Vaillant;BAI00;0200;7503
2026-03-02 18:32:39.335 [update notice] store 08 ident: done
2026-03-02 18:32:39.335 [update notice] sent scan-read scan.08 QQ=31: Vaillant;BAI00;0200;7503
2026-03-02 18:32:39.335 [bus notice] scan 08: ;Vaillant;BAI00;0200;7503
2026-03-02 18:32:39.336 [main notice] read common config file vaillant/broadcast.csv
2026-03-02 18:32:39.336 [main notice] read common config file vaillant/general.csv
2026-03-02 18:32:39.336 [main notice] read common config file vaillant/scan.csv
2026-03-02 18:32:39.336 [main notice] read scan config file vaillant/08.bai.csv for ID "bai00", SW0200, HW7503
2026-03-02 18:32:39.508 [update notice] sent scan-read Scan.08 Id QQ=31:
2026-03-02 18:32:39.682 [update notice] sent scan-read Scan.08 Id QQ=31:
2026-03-02 18:32:39.853 [update notice] sent scan-read Scan.08 Id QQ=31:
2026-03-02 18:32:40.004 [bus notice] max. symbols per second: 107
2026-03-02 18:32:40.033 [update notice] sent scan-read Scan.08 Id QQ=31: 21;25;12;0010023673;3130;316592;N0
2026-03-02 18:32:40.037 [main notice] found messages: 236 (3 conditional on 35 conditions, 0 poll, 16 update)
2026-03-02 18:32:40.200 [update notice] sent scan-read Scan.08 Id QQ=31: 21;25;12;0010023673;3130;316592;N0
2026-03-02 18:32:40.368 [update notice] sent scan-read Scan.08 Id QQ=31: 21;25;12;0010023673;3130;316592;N0
2026-03-02 18:32:40.552 [update notice] sent scan-read Scan.08 Id QQ=31: 21;25;12;0010023673;3130;316592;N0
2026-03-02 18:32:40.729 [update notice] sent scan-read Scan.08 Id QQ=31: 21;25;12;0010023673;3130;316592;N0
2026-03-02 18:32:40.729 [bus notice] scan 08: ;21;25;12;0010023673;3130;316592;N0
2026-03-02 18:32:50.902 [update notice] sent poll-read bai CounterStartattempts1 QQ=31: 0
2026-03-02 18:32:56.182 [update notice] sent poll-read bai CounterStartattempts2 QQ=31: 0
2026-03-02 18:33:02.168 [update notice] sent poll-read bai CounterStartAttempts3 QQ=31: 0
2026-03-02 18:33:08.196 [update notice] sent poll-read bai CounterStartAttempts4 QQ=31: 0
2026-03-02 18:33:12.914 [main error] scan config 05: ERR: read timeout
2026-03-02 18:33:14.158 [update notice] sent poll-read bai DcfState QQ=31: nosignal
2026-03-02 18:33:14.916 [main notice] scan completed 1 time(s), check again
2026-03-02 18:33:20.159 [update notice] sent poll-read bai DeactivationsTemplimiter QQ=31: 0
2026-03-02 18:33:26.174 [update notice] sent poll-read bai DisplayMode QQ=31: 2
2026-03-02 18:33:32.186 [update notice] sent poll-read bai Expertlevel_ReturnTemp QQ=31: -1.81;cutoff
2026-03-02 18:33:38.184 [update error] unable to parse poll-read bai ExternalFlowTempDesired from 3108b509030d2500 / 00: ERR: invalid position
2026-03-02 18:33:39.958 [mqtt error] decode bai ExternalFlowTempDesired: ERR: invalid position
2026-03-02 18:33:44.165 [update error] unable to parse poll-read bai ExtFlowTempDesiredMin from 3108b509030d6e04 / 00: ERR: invalid position
2026-03-02 18:33:49.974 [mqtt error] decode bai ExtFlowTempDesiredMin: ERR: invalid position
2026-03-02 18:33:50.189 [update notice] sent poll-read bai FanHours QQ=31: -
2026-03-02 18:33:56.136 [update notice] sent poll-read bai FanStarts QQ=31: -
2026-03-02 18:34:02.224 [bus error] poll bai FlowTemp failed: ERR: read timeout
2026-03-02 18:34:08.191 [update notice] sent poll-read bai FlowTempDesired QQ=31: 25.00
2026-03-02 18:34:14.150 [update notice] sent poll-read bai FlowTempMax QQ=31: 0.00
2026-03-02 18:34:20.164 [update notice] sent poll-read bai HcHours QQ=31: 0
2026-03-02 18:34:25.103 [main error] scan config 05: ERR: read timeout
2026-03-02 18:34:26.210 [update error] unable to parse poll-read bai HcPumpMode from 3108b509030d4904 / 00: ERR: invalid position
2026-03-02 18:34:27.105 [main notice] scan completed 2 time(s), check again
2026-03-02 18:34:27.111 [mqtt error] decode bai HcPumpMode: ERR: invalid position
2026-03-02 18:34:32.184 [update notice] sent poll-read bai HcPumpStarts QQ=31: -
2026-03-02 18:34:38.175 [update notice] sent poll-read bai HcStarts QQ=31: 0
2026-03-02 18:34:44.170 [update notice] sent poll-read bai HcUnderHundredStarts QQ=31: 0
2026-03-02 18:34:47.231 [device notice] extra info: ID ccba97f8e604480200
2026-03-02 18:34:47.331 [main notice] update check: OK, device firmware 1[6301] available, broadcast.csv: different version available, memory.csv: different version available, vaillant/08.bai.csv: different version available, vaillant/bai.308523.inc: different version available, vaillant/broadcast.csv: different version available, vaillant/general.csv: different version available, vaillant/scan.csv: different version available
2026-03-02 18:34:50.191 [update error] unable to parse poll-read bai HoursTillService from 3108b509030d2004 / 00: ERR: invalid position
2026-03-02 18:34:52.345 [mqtt error] decode bai HoursTillService: ERR: invalid position
2026-03-02 18:34:56.156 [update notice] sent poll-read bai HwcHours QQ=31: 0
2026-03-02 18:35:00.357 [update notice] sent update-write bai SetModeOverride QQ=31: off;25.0;0.0;0;0;0;0;0;0;1
2026-03-02 18:35:00.357 [mqtt notice] write bai SetModeOverride: 1;25.0;0;0;0;0;0;0;0;1;0;0
2026-03-02 18:35:02.180 [update error] unable to parse poll-read bai HwcPostrunTime from 3108b509030d1104 / 00: ERR: invalid position
2026-03-02 18:35:07.370 [mqtt error] decode bai HwcPostrunTime: ERR: invalid position
2026-03-02 18:35:08.164 [update notice] sent poll-read bai HwcStarts QQ=31: 0
2026-03-02 18:35:14.847 [bus error] poll bai HwcTemp failed: ERR: read timeout
2026-03-02 18:35:20.158 [update notice] sent poll-read bai HwcTempDesired QQ=31: 15.00
2026-03-02 18:35:26.171 [update error] unable to parse poll-read bai HwcTempMax from 3108b509030d4304 / 00: ERR: invalid position
2026-03-02 18:35:27.417 [mqtt error] decode bai HwcTempMax: ERR: invalid position
2026-03-02 18:35:32.163 [update notice] sent poll-read bai HwcUnderHundredStarts QQ=31: 0
2026-03-02 18:35:37.721 [main error] scan config 05: ERR: read timeout
2026-03-02 18:35:38.252 [update notice] sent poll-read bai HwcWaterflow QQ=31: 0.00
2026-03-02 18:35:39.722 [main notice] scan completed 3 time(s), check again
2026-03-02 18:35:44.164 [update notice] sent poll-read bai HwcWaterflowMax QQ=31: 0.00
2026-03-02 18:35:50.174 [update notice] sent poll-read bai Maintenancedata_HwcTempMax QQ=31: 0.00
2026-03-02 18:35:56.181 [update notice] sent poll-read bai OutdoorstempSensor QQ=31: -60.44;cutoff
2026-03-02 18:36:02.205 [update notice] sent poll-read bai PowerValue QQ=31: 11 02 64 0e 64 0e
2026-03-02 18:36:08.174 [update notice] sent poll-read bai PrVortexFlowSensorValue QQ=31: -1
2026-03-02 18:36:14.185 [update notice] sent poll-read bai PumpHours QQ=31: -
2026-03-02 18:36:20.147 [update notice] sent poll-read bai PumpPower QQ=31: 0
2026-03-02 18:36:26.143 [update notice] sent poll-read bai PumpPowerDesired QQ=31: auto
2026-03-02 18:36:32.194 [update notice] sent poll-read bai ReturnTemp QQ=31: 0.00;-;ok
2026-03-02 18:36:38.185 [update notice] sent poll-read bai ReturnTempMax QQ=31: 0.00
2026-03-02 18:36:44.155 [update error] unable to parse poll-read bai SecondPumpMode from 3108b509030d0b04 / 00: ERR: invalid position
2026-03-02 18:36:49.914 [main error] scan config 05: ERR: read timeout
2026-03-02 18:36:49.915 [mqtt error] decode bai SecondPumpMode: ERR: invalid position
2026-03-02 18:36:50.459 [update notice] sent poll-read bai SHEMaxFlowTemp QQ=31: -0.06
2026-03-02 18:36:51.916 [main notice] scan completed 4 time(s), check again
2026-03-02 18:36:56.166 [update notice] sent poll-read bai Statenumber QQ=31: 31
2026-03-02 18:37:02.170 [update notice] sent poll-read bai Status01 QQ=31: 18.0;0.0;-;0.0;-;off
2026-03-02 18:37:08.196 [update notice] sent poll-read bai Status02 QQ=31: auto;50;80.0;70;70.0
2026-03-02 18:37:14.140 [update error] unable to parse poll-read bai Status16 from 3108b5040116 / 00: ERR: invalid position
2026-03-02 18:37:17.010 [mqtt error] decode bai Status16: ERR: invalid position
2026-03-02 18:37:20.177 [update error] unable to parse poll-read bai Status from 3108b5110103 / 00: ERR: invalid position
2026-03-02 18:37:22.017 [mqtt error] decode bai Status: ERR: invalid position
2026-03-02 18:37:26.174 [update notice] sent poll-read bai StorageLoadPumpHours QQ=31: -
2026-03-02 18:37:32.157 [update notice] sent poll-read bai StorageloadPumpStarts QQ=31: -
2026-03-02 18:37:38.188 [update notice] sent poll-read bai StorageTemp QQ=31: -14.94;cutoff
2026-03-02 18:37:44.155 [update notice] sent poll-read bai StorageTempDesired QQ=31: 15.00
2026-03-02 18:37:50.161 [update notice] sent poll-read bai StorageTempMax QQ=31: 0.00
2026-03-02 18:37:56.173 [update notice] sent poll-read bai TempDiffBlock QQ=31: 0
2026-03-02 18:38:02.104 [main error] scan config 05: ERR: read timeout
2026-03-02 18:38:02.653 [update notice] sent poll-read bai TempDiffFailure QQ=31: 0
2026-03-02 18:38:04.106 [main notice] scan completed 5 time(s), check again
2026-03-02 18:38:08.175 [update notice] sent poll-read bai TempGradientFailure QQ=31: 0
2026-03-02 18:38:14.174 [update notice] sent poll-read bai Templimiter QQ=31: off
2026-03-02 18:38:20.177 [update notice] sent poll-read bai TemplimiterWithNTC QQ=31: no
2026-03-02 18:38:26.183 [update notice] sent poll-read bai TempMaxDiffExtTFT QQ=31: -0.06
2026-03-02 18:38:32.630 [update error] unable to parse poll-read bai ValveMode from 3108b509030d2a04 / 00: ERR: invalid position
2026-03-02 18:38:34.153 [mqtt error] decode bai ValveMode: ERR: invalid position
2026-03-02 18:38:38.155 [update notice] sent poll-read bai ValveStarts QQ=31: -
2026-03-02 18:38:44.153 [update error] unable to parse poll-read bai VortexFlowSensor from 3108b509030dd500 / 00: ERR: invalid position
2026-03-02 18:38:49.175 [mqtt error] decode bai VortexFlowSensor: ERR: invalid position
2026-03-02 18:38:50.146 [update notice] sent poll-read bai WaterHcFlowMax QQ=31: -
2026-03-02 18:38:56.159 [update notice] sent poll-read bai WaterPressure QQ=31: 1.479;ok
2026-03-02 18:39:02.167 [update notice] sent poll-read bai WaterpressureBranchControlOff QQ=31: on
2026-03-02 18:39:08.174 [update notice] sent poll-read bai WaterpressureMeasureCounter QQ=31: -
2026-03-02 18:39:14.190 [update notice] sent poll-read bai WaterpressureVariantSum QQ=31: -
2026-03-02 18:39:14.361 [main error] scan config 05: ERR: read timeout
2026-03-02 18:39:16.363 [main notice] scan completed 6 time(s), end
2026-03-02 18:39:20.153 [update error] unable to parse poll-read bai WPPostrunTime from 3108b509030df703 / 00: ERR: invalid position
2026-03-02 18:39:21.371 [mqtt error] decode bai WPPostrunTime: ERR: invalid position
2026-03-02 18:39:26.151 [update notice] sent poll-read bai CounterStartattempts1 QQ=31: 0
2026-03-02 18:39:32.185 [update notice] sent poll-read bai CounterStartattempts2 QQ=31: 0
2026-03-02 18:39:38.134 [update notice] sent poll-read bai CounterStartAttempts3 QQ=31: 0
2026-03-02 18:39:44.176 [update notice] sent poll-read bai CounterStartAttempts4 QQ=31: 0
2026-03-02 18:39:50.174 [update notice] sent poll-read bai DcfState QQ=31: nosignal
2026-03-02 18:39:56.173 [update notice] sent poll-read bai DeactivationsTemplimiter QQ=31: 0
2026-03-02 18:40:00.366 [update notice] sent update-write bai SetModeOverride QQ=31: off;25.0;0.0;0;0;0;0;0;0;1
2026-03-02 18:40:00.366 [mqtt notice] write bai SetModeOverride: 1;25.0;0;0;0;0;0;0;0;1;0;0
2026-03-02 18:40:02.164 [update notice] sent poll-read bai DisplayMode QQ=31: 2
2026-03-02 18:40:08.184 [update notice] sent poll-read bai Expertlevel_ReturnTemp QQ=31: -1.81;cutoff
2026-03-02 18:40:14.186 [update error] unable to parse poll-read bai ExternalFlowTempDesired from 3108b509030d2500 / 00: ERR: invalid position
2026-03-02 18:40:16.439 [mqtt error] decode bai ExternalFlowTempDesired: ERR: invalid position
2026-03-02 18:40:20.158 [update error] unable to parse poll-read bai ExtFlowTempDesiredMin from 3108b509030d6e04 / 00: ERR: invalid position
2026-03-02 18:40:21.446 [mqtt error] decode bai ExtFlowTempDesiredMin: ERR: invalid position
2026-03-02 18:40:26.174 [update notice] sent poll-read bai FanHours QQ=31: -
2026-03-02 18:40:32.154 [update notice] sent poll-read bai FanStarts QQ=31: -