Skip to content

Latest commit

 

History

History
250 lines (202 loc) · 12.7 KB

power.md

File metadata and controls

250 lines (202 loc) · 12.7 KB

Modeled power and energy

Op-level FPE returns operation energy. Native Replay accumulates that evidence and computes the coverage-gated power summary. Unified prediction and recommendation preserve and display power_w and power_coverage; predict --detail energy exposes available breakdown evidence. In native Replay and unified prediction, whole-forward FPM, fixed, and polynomial timing remain latency-only. EPD's combined report keeps unified power unavailable even when its encoder has separate analytical power.

Python static FPM summaries have a separate operation-energy path: with SOL interpolation and powered schema-8 rows, get_context_energy_wms_dict() and get_generation_energy_wms_dict() return nonzero FPM energy. Direct interpolation stays latency-only. Mixed steps report zero FPM prefill and marginal-decode energy (D10, AISIM-2001), while retaining draft-operation energy. SDK and legacy cli_estimate() static, aggregated, and disaggregated results apply the 90% coverage gate to FPM watts: they publish numeric power_w for powered schema-8 pairs at or above the gate, and null power with numeric coverage below it. Aggregated coverage counts mixed-step latency as uncovered, because mixed-step FPM energy is suppressed while pure-decode energy is retained; the published power_w divides total energy by total active latency. Non-schema-8 FPM runs (schema 6 and 7) have no row-power evidence and publish null power_w (None in Python), rather than the previous 0.0 sentinel. A disaggregated result withholds power when either worker withholds it. FPM watts are also withheld for draft speculation schemes, models with encoder operations, and language-only EPD workers. Raw InferenceSession summaries provide coverage through get_power_data_coverage(); Task.run_single_agg() and Task.run_single_disagg() include power_coverage in their rows. The operation energy stays available below the gate, and static operation energy does not enable replay or unified power_w publication. See schema-8 behavior for the interpolation contract.

The current producers and consumers are Replay reports, power validation/presentation, and Sweeper results. The synthetic contract fixture checks semantics, not measured accuracy.

Scope and units

power_w is the active forward-pass average power of one GPU, in watts. It is derived from modeled operation energy and modeled active latency. It is not:

  • whole-cluster power or the sum across workers;
  • wall-plug, CPU, host-memory, networking, storage, or cooling power;
  • idle power between forward passes; or
  • a measurement of the simulated deployment.

Operation energy uses watt-milliseconds (energy_wms). Operation and phase latency use milliseconds (latency_ms). Dividing summed energy_wms by summed latency_ms therefore yields watts without a unit conversion.

AFD execution plans sum energy and active GPU time across the participating ranks, then divide both totals by the pool pair's GPU count for per-GPU evidence. Uneven token slices use each nonempty rank's actual operation time. The pipeline latency still uses the slowest rank; it is not the denominator for active-operation power. Uncovered operations retain their active time in the coverage calculation.

AFD timing and energy use the same operator queries and batch-pricing rules: embedding joins a dense prefix once at full replica batch, otherwise it runs per microbatch; logits always run per microbatch. Decode queries timing and energy with the actual batch size and mean context length on every pass. Prefill uses actual batch and uncached tokens for both timing and evidence.

These values are modeling evidence. They must retain the timing provider, performance-data identity, operation source, backend/version, hardware, and role topology needed to interpret them. They are not a replacement for hardware validation.

Operation evidence and coverage

For every modeled operation i, let:

  • L_i be its finite, non-negative active latency in milliseconds; and
  • E_i be its finite, non-negative energy in watt-milliseconds.

An operation is power-covered only when E_i > 0. A zero energy value is the missing-data sentinel; it must not be interpreted as a zero-power operation. Coverage is weighted by active latency so many short covered operations cannot hide one long uncovered operation:

total_latency_ms   = sum(L_i)
covered_latency_ms = sum(L_i where E_i > 0)
power_coverage     = covered_latency_ms / total_latency_ms
power_w            = sum(E_i) / total_latency_ms

When total_latency_ms is zero, power_coverage is 0 and power_w is unavailable. Implementations clamp a computed coverage ratio to [0, 1] after validating the inputs; they must reject non-finite or negative evidence instead of silently repairing it.

Publication gate

AISim uses AIC's fail-closed 90% coverage threshold. A numeric power_w may be published only when every condition below is true:

  1. every replay role uses a timing provider that supplies operation-energy evidence;
  2. total modeled active latency is positive;
  3. power_coverage >= 0.9; and
  4. the resulting power is finite and positive.

Coverage is based on modeled active time, not operation count. If operations covering 90 ms of a 100 ms forward pass have energy data, power_coverage is 0.90. Because the threshold is inclusive, exactly 0.90 is sufficient; 0.899 is not. Below the threshold, JSON output keeps numeric power_coverage and sets power_w to null, allowing a consumer to distinguish insufficient data from an unsupported energy path. A provider with an energy channel but no covered operations therefore reports power_coverage: 0 and power_w: null.

Native Replay's fixed, polynomial, and forward-pass-metrics (FPM) timing providers do not supply an energy channel. A replay using any of those providers, or mixing an energy-aware role with an energy-unaware role, returns power_w: null and power_coverage: null, including with a fully powered schema-8 FPM pair. Unified prediction preserves these nulls. The null values never mean zero watts or zero coverage.

Aggregate and disaggregated deployments

Aggregation always happens on energy and active latency, never by taking an unweighted mean of already averaged power values.

For an aggregated deployment, all prefill and decode forward-pass invocations from the aggregated role contribute their operation energy, active latency, and covered active latency.

For a disaggregated deployment, the prefill and decode roles are combined by the same sums:

power_w = (prefill_energy_wms + decode_energy_wms)
          / (prefill_active_latency_ms + decode_active_latency_ms)

power_coverage uses the corresponding covered-latency numerator across both roles. This is a latency-weighted per-GPU mean across the modeled P+D request path, not the sum of prefill-GPU and decode-GPU power and not a fleet power estimate. Role-specific topology and timing provenance remain explicit.

If a configured timing speedup changes modeled active time, both that phase's energy and latency evidence are scaled by the same factor before aggregation. This preserves the phase-average power while changing its weight in the end-to-end result.

Analytical encoder/EPD and attention/FFN-disaggregated (AFD) overlays do not provide a qualified combined operation-energy report. Their unified power summary remains unavailable; an encoder-specific field is not a combined deployment estimate.

Output contract

Replay JSON and prediction summaries include both fields. Each value is a number or null:

Field Unit JSON value (key always present)
power_coverage Ratio in [0, 1] Numeric for a supported energy-aware path, including below the gate and at zero coverage; otherwise null.
power_w W/GPU Numeric only when power_coverage >= 0.9 and the other publication conditions hold; otherwise null.

For example, insufficient coverage returns {"power_w": null, "power_coverage": 0.75}. An unsupported energy provider returns {"power_w": null, "power_coverage": null}. Qualifying synthetic evidence can return {"power_w": 450, "power_coverage": 0.9}.

The machine-readable fragment is schemas/power-metrics-v1.schema.json. It deliberately permits unrelated report metrics so it can validate both a replay report and a Sweeper candidate's metrics object.

Recommendation results with a valid replay report retain both fields in candidates[].metrics using the same names, units, and null semantics. candidates[].provenance.power repeat both values, including nulls, and may add evidence metadata such as the method, threshold, role, and source identities. It must not contain numeric watts when candidate metrics contain power_w: null. Failed attempts without a valid replay report retain the existing empty-metrics envelope; they have no power summary to validate.

Normal summaries and optional energy details

Normal human-readable predict summaries and each displayed recommend candidate row must always show both power_w and power_coverage labels, without requiring --detail. Watts are per GPU; display numeric coverage as a percentage. When a value is unavailable, keep its label and show unavailable with a short reason:

  • Qualifying evidence: show numeric watts and coverage.
  • Coverage below 90%: show unavailable watts and the computed coverage ratio, including 0% when an energy-aware provider has no covered operations.
  • Zero active latency on an energy-aware path: show unavailable watts and 0% coverage, with a reason identifying the absence of active latency.
  • Unsupported providers or topologies, including a role without an energy channel: show both values as unavailable; do not invent 0 W or 0%.

The predict --detail energy selector adds phase and per-operation energy evidence to that normal summary. It must not change summary power, coverage, or the publication gate. Missing breakdown evidence must carry an unavailable reason. A detail request cannot promote partial or unsupported evidence into a qualified summary value. Recommendation details use predict on a saved candidate YAML; this contract does not add recommend --detail.

Both JSON keys are mandatory, independent of detail selection. JSON retains numeric coverage when it can be computed, sets unavailable watts to null, and sets both values to null when the provider or topology cannot supply the required energy evidence. CSV exporters use an empty field for each null value. Unavailable values must not be serialized as strings or zero watts. Before validating or serializing a host-language metrics object, producers must reject NaN and positive or negative infinity; permissive encoder extensions are not valid JSON values under this contract.

Provenance boundary

At minimum, a consumer must be able to recover the concrete model, hardware, backend and version, aggregate or disaggregated topology, timing provider per role, performance-data source/revision, operation source, coverage threshold, and computed coverage. Unknown runner metadata remains preserved under the existing runner_metadata escape hatch until promoted to a typed field.

Modeled power and measured runtime or telemetry power must never share an unqualified field. power_w is reserved for the modeled active-forward-pass quantity in this contract. A future measured value must use a distinct name and provenance that states its measurement boundary.

Compatibility rules

This is the v1 modeled-power contract. Conforming producers must emit both keys and use null for unavailable values. Legacy reports produced before this integration may lack the keys; readers may treat that legacy absence as unavailable, but such reports do not satisfy this schema. Consumers must handle nulls before numeric formatting, arithmetic, or ranking. Neither a null nor an absent legacy value may be coerced to zero.

Changing a field name, unit, scope, aggregation formula, missing-value rule, or the 0.9 gate is a breaking semantic change. It requires a versioned schema and an explicit converter or coordinated result-schema version bump. Adding new optional provenance details is backward-compatible when existing meanings do not change.